Create Spec Sheet

Roof Assembly 23934

Owner: Carlisle SynTec


Roof

Single Ply
New Roof
Re-Roof
Recover

Deck

Wood
Wood Plank Min. Thickness: 19/32 inches
Plywood Min. Thickness: 19/32 inches
24" joist spans / 8d ring shank nails 6" oc

Performance

150 psf
FM 4474 (2010/2011)

Layer Summary

Adhered PVC Single Ply Membrane
Fastened Gypsum Fiber Coverboard
(Optional) Loose Laid Polyisocyanurate Insulation or Expanded Polystyrene Insulation or Extruded Polystyrene Insulation
Wood

Layer Details

Layer 3 - Adhered PVC Single Ply Membrane
Product Choices Product Classification Required Attributes Lap Requirements


PVC Single Ply Membrane Not specified Heat Weld
2" sheet lap / 1.5" heat weld
Securement Choices Securement Rate Securement Details


1 gallon per square 1 gallon per square achieved by full spray or ribbons spaced 4" oc.
Layer 2 - Fastened Gypsum Fiber Coverboard
Product Choices Product Classification Required Attributes


Gypsum Fiber Coverboard Min. Thickness: 0.5 inches
Securement Choices Securement Rate Securement Details
with
1 fastener per 2 square feet Not specified
Layer 1 (Optional) - Loose Laid Polyisocyanurate Insulation, Expanded Polystyrene Insulation, Extruded Polystyrene Insulation
Product Choices Product Classification Required Attributes


Polyisocyanurate Insulation Any Thickness


Expanded Polystyrene Insulation Any Thickness


Extruded Polystyrene Insulation Any Thickness
Securement Choices Securement Rate Securement Details
N/A N/A Not specified
Last verified on 3/12/2024.
Sponsored by 
Administered by 
Create Spec Sheet