Owner: Carlisle SynTec
Product Choices | Product Classification | Required Attributes | Lap Requirements |
---|---|---|---|
|
PVC Single Ply Membrane | Not specified |
Heat Weld 2" sheet lap / 1.5" heat weld |
Securement Choices | Securement Rate | Securement Details |
---|---|---|
|
1 gallon per square | 1 gallon per square achieved by full spray or ribbons spaced 4" oc. |
Product Choices | Product Classification | Required Attributes |
---|---|---|
|
Gypsum Fiber Coverboard | Min. Thickness: 0.5 inches |
Securement Choices | Securement Rate | Securement Details |
---|---|---|
with |
1 fastener per 2 square feet | Not specified |
Product Choices | Product Classification | Required Attributes |
---|---|---|
|
Polyisocyanurate Insulation | Any Thickness |
|
Expanded Polystyrene Insulation | Any Thickness |
|
Extruded Polystyrene Insulation | Any Thickness |
Securement Choices | Securement Rate | Securement Details |
---|---|---|
N/A | N/A | Not specified |
The Directory of Roof Assemblies (DORA) is a single-source database of low slope roof systems tested in accordance with standards referenced in the International Building Code to meet wind uplift requirements. This service has been developed to be a reference source easily used by owners, design professionals, roof consultants, code officials and other users. DORA is sponsored by SPRI and administered by Intertek.
For all assemblies, refer to the Listing Owner's installation and application instructions.
For recover applications, ensure the existing roof system meets or exceeds the performance rating of the system to be applied.
Tapered versions of the insulations noted in the assembly may be used. When a minimum thickness is required, the thinnest portion of the taper must meet that requirement.
Unless otherwise specified, this Listing makes no recommendations or requirements for the structural system to which the system is to be applied. Evaluation of the structural integrity of the deck to which the assembly is to be applied is the responsibility of the engineer or architect of record for the project.
Unless otherwise specified, please refer to the manufacturer’s roof specification and installation instructions for proper use and application of the roofing assembly’s materials and components, including fastener penetration or embedment, to help ensure proper performance of the roof assembly system.